Outdoor Drop Wire


  • Used for outdoor service wire to the subscriber premises.
  •  Outer jacketing material is Polyethylene in accordance with the international standards.
  • Conductor
    The hard drawn copper wires, which are parallel to each other, coated by polyethylene.

    Insulation
    Used for outdoor service wire to the subscriber premises. Outer jacketing material is Polyethylene in accordance with the international standards.

    Additional Information
    Note:  Coil length is 500 (±%5) meters

 

a
mm
d
mm
r
mm
s
mm
g
mm
l
mm

Nominal Values

 
0,8 2,8 0,3 0,5 3,1 5,9
0,9 2,9 0,3 0,5 3,2 6,1
1,0 3,0 0,3 0,5 3,3 6,3
Tolerance (±) 0,012 0,1 0,1 0,2 0,2 0,5

 

Conductor Size   0,8(mm) 0,9(mm) 1,0(mm)
Resistance Max 36,78 28,96 23,39
Insulation Resistance 500 V DC (G Ohm km) Min 10
Dielectric Strength (KV DC for 1 min) Min 6,0