X
+970-2-2422931 | info@nextwave.ps

Air Core Self Supported Aerial Telephone Cables


  • Used for aerial installation.
  • The cable structure is completed by the application of a suitable core wrapping material, copolymer coated moisture barrier, a parallel support messenger that with the core are covered by an overall the black outer jacketing.
  • Outer jacketing material is MDPE, LDPE or HDPE in accordance with ASTM D 1248.
  • These types of cables have excellent mechanical performance.
  • Conductor
    Solid annealed electrolytic copper. The conductor sizes are 0.4, 0.5, 0.6, or 0.9 mm

    Color Coding
    Fully color-coding.

    Insulation
    Colored foam skin polyethylene insulation and solid insulation in according to ASTM 1248, foam skin insulation with cellular polyethylene covered with skin layer of high density polyethylene compound. Solid insulation made by medium or high-density polyethylene compound.

    Twisting / Quadding
    Two or four insulated wire twisted together. The twist length specially designed to minimize the capacitance unbalance and cross talk.

    Cable Core
    Twisted wires are assembled to form substantially cylindrical groups of ten pairs (units). Super units are assembled by suitable number of units which are binded with durable colored tapes and cabled to complete cable core.

    Core Wrapping
    Anon-hydroscopic and dielectric polyester tape is applied helically over the cable core. Applied polyester tape at least overlaps by 5%.

    Identification
    A plastic tape, durable marked by the manufacturer name, year of manufacture, and cable size (if required) is placed under the core wrapping.
     
    Inner Jacket
    An extruded black low-density or medium density polyethylene in accordance with ASTM D 1248 encloses the cable core.

    Screen
    A single flat aluminum tape (0,15 mm thickness of aluminum) coated both side 50 micron polyethylene film applied longitudinally over core covering with an min 5 mm overlap.

    Support Messenger
    According to ASTM A 475-66T galvanized 7 steel wires stranded rope having minimum 120 kg/mm2 is used as holding rope.

    Outer Jacket
    Over the corrugated steel tape, outer jacket is extruded black low-density polyethylene or medium density polyethylene in accordance with ASTM D 1248. Outer jacket polyethylene is include %2,5 ± 0,5 carbon black for sunrise resistance.

    Cable Construction
  • Steel holding rope
  • Conductor & Insulation
  • Core Wrapping
  • Aluminum Foil
  • Outer Sheath
  • Type Code of Cable
    A-02Y(L) T 2Y mxn Refer to the type code of the copper cable for the description of the cable code. Sequentially numbered length marking are printed on the outside of cable jacket by hot foil printing method

     

0,4 mm Conductor

Number of Pair Outer Diameter of Cable mm Weight of Copper Kg/km (Nom) App. Cable Weight Kg/Km) Reel Length (m)* ± %5
10   22,6 140 2.000
20   45,3 190 2.000
30   67,9 220 2.000
50   115,5 310 1.000
100   231,0 490 1.000
150   346,5 680 500
200   462,0 910 500

 

0,5 mm Conductor

Number of Pair Outer Diameter of Cable mm Weight of Copper Kg/km (Nom) App. Cable Weight Kg/Km) Reel Length (m)* ± %5
10   35,5 180 2.000
20   71,1 240 2.000
30   106,6 290 1.000
50   181,2 410 1.000
100   362,4 680 500
150   543,6 970 500
200   724,8 1.220 500

 

0,6 mm Conductor

Number of Pair Outer Diameter of Cable mm Weight of Copper Kg/km (Nom) App. Cable Weight Kg/Km) Reel Length (m)* ± %5
10   51,2 190 1.200
20   102,3 280 1.200
30   153,5 380 1.200
50   260,9 550 1.200
100   521,8 950 800
150   782,8 1320 400
200   1043,7 1.730 400

 

0,9 mm Conductor

Number of Pair Outer Diameter of Cable mm Weight of Copper Kg/km (Nom) App. Cable Weight Kg/Km) Reel Length (m)* ± %5
10   115,2 310 1.200
20   230,2 460 1.200
30 19,0x30,0 345,3 650 800
50   587,1 1.030 800
100   1174,1 1.860 400

Sales Ticket Form